Properties
Fas­ten­ing type on con­nec­tion plate,
Per­ma­nently screwed
Prod­uct weight [g] 2.200
Dis­play Seven seg­ment dis­play
Per­mis­sion RCM mark,
c UL us - Listed (OL)
CE cer­tifi­cate (see de­c­la­ra­tion of con­for­mity) acc. to EU-​EMV Di­rec­tive,
acc. to EU Ma­chine Di­rec­tive,
acc. to EU Low volt­age Di­rec­tive,
acc. to EU-​RoHS Di­rec­tive
Bear­ing tem­per­a­ture [°C] -25 to 70
am­bi­ent tem­per­a­ture [°C] 0 to 40
Rel­a­tive hu­mid­ity 0 - 90 %
Pro­tec­tion cat­e­gory IP10,
IP20
De­gree of con­t­a­m­i­na­tion 2
Ma­te­r­ial in­for­ma­tion LABS con­tain­ing ma­te­ri­als in­cluded,
RoHs com­pli­ant
Phase nom­i­nal op­er­at­ing volt­age 1-​phase
Nom­i­nal op­er­at­ing volt­age AC [V] 230
Per­mit­ted volt­age os­cil­la­tions ± 10 %
Net­work fre­quency [Hz] 50 to 60
Nom­i­nal cur­rent [A] 4 to 6
Net­work fil­ter in­te­grated
Max. in­ter­me­di­ate cir­cuit volt­age DC [V] 320
Brak­ing re­sis­tance [Ohm] 60
Im­pulse power brak­ing re­sis­tance [kVA] 2,8
Nom­i­nal volt­age logic sup­ply DC [V] 24
Per­mit­ted range logic volt­age ± 20 %
Power input logic sup­ply with­out park­ing brake [A] 0,65
Out­put volt­age range AC 3x 0 - 270 V
Nom­i­nal out­put cur­rent [A] 5,0
Nom­i­nal cur­rent per phase, ef­fec­tive [A] 5,0
Peak cur­rent per phase, ef­fec­tive [A] 10
Max. peak cur­rent du­ra­tion [s] 5
Nom­i­nal per­for­mance con­troller [VA] 1.000
Peak per­for­mance [VA] 2.000
Out­put fre­quency [Hz] 0 to 1000
Pa­ra­me­ter­is­ing in­ter­face USB,
Eth­er­net,
Pa­ra­me­ter­is­ing and com­mis­sion­ing
Field­bus cou­pling CANopen,
Mod­bus/TCP
Com­mu­ni­ca­tion pro­file DS301/DSP402
Process cou­pling I/O cou­pling,
for 256 mo­bile sets
Max. field­bus trans­fer rate [Mbit/s] 1
Bus con­nec­tor Sub-D,
9 pin,
Plug
En­coder out­put in­ter­face, prop­er­ties Res­o­lu­tion 16384 ppr
En­coder out­put in­ter­face, func­tion Ac­tual value feed­back via en­coder sig­nals for speed con­trol mode,
Tar­get value for down­stream switched slave ac­tu­a­tor
En­coder input in­ter­face, prop­er­ties EnDat,
HIPER­FACE,
RS422,
SIN­COS,
3 phase en­coder sig­nals
En­coder input in­ter­face, func­tion In syn­chro­nous mode as a speed pre­set of the slave ac­tu­a­tor,
En­coder sig­nal tar­get speed value
Quan­tity dig­i­tal logic in­puts 10
Prop­er­ties logic in­puts Freely con­fig­urable,
Gal­van­i­cally sep­a­rated
Work area logic input [V] 8 to 30
Quan­tity dig­i­tal logic out­puts 24 V DC 5
Prop­er­ties dig­i­tal logic out­puts Gal­van­i­cally sep­a­rated,
Par­tially freely con­fig­urable
Max. cur­rent dig­i­tal logic out­puts [mA] 100
Quan­tity ana­logue tar­get value in­puts 2
Prop­er­ties tar­get value in­puts Dif­fer­en­tial in­puts,
Con­fig­urable for speed,
Con­fig­urable for cur­rent
Work area tar­get value input ± 10 V
Im­ped­ance tar­get value input [kOhm] 20
Quan­tity ana­logue mon­i­tor out­puts 2
Work area mon­i­tor out­puts ± 10 V
Res­o­lu­tion mon­i­tor out­puts [Bit] 9
Prop­er­ties mon­i­tor out­puts Short cir­cuit proof
Cer­ti­fied award­ing point 01/205/5162.02/19,
TÜV Rhein­land
Ac­tive PFC yes
Safety func­tion Safe switched off torque (STO),
Safe stop 1 (SS1)
Safety In­tegrity Level (SIL) Safe switched off torque (STO) / SIL 3 / SILCL 3
Per­for­mance Level (PL) Safe switched off torque (STO) / cat­e­gory 4 per­for­mance level e
Di­ag­nose de­gree of cov­er­age [%] 97
SFF Safe Fail­ure Frac­tion [%] 99,17
Hard­ware error tol­er­ance 1
Proof test in­ter­val [A] 20